Prepare Important Exam with 010-151 Exam Dumps(2023)
Pass Exam Questions Efficiently With 010-151 Questions
More about the Exam
In 010-151 exam, 65-75 questions will appear. The applicants need to be ready to tackle MCQs, testlets, drag-and-drops, and items of other types. Regarding time, there will be 90 minutes to explore and complete the test. The only available language for 010-151 is English.
How do you start to study for the Cisco Certified Technician Data Center (010-151) Exam
Get the guide For Cisco Certified Technician Data Center (010-151) Exam
Quick study guide if you don't have time to read complete the page
The Cisco Certified Data Center Technician (CCT) validates the skills of a technician in the following areas;
- The basic configuration of Cisco NX-OS
- Cisco data center products and hardware with a focus on the Cisco Unified Computing System (UCS). The program covers repair (hardware failure solution) services on Cisco Data Center products, including hardware replacement, backup and recovery of software and configuration, verification of safety and environmental requirements, recognition of type in the required connection and cables and performs basic physical layer troubleshooting. The Cisco Certified Technician (CCT) must be competent in the following areas; basic configuration of Cisco NX-OS, Cisco Data Center products and hardware components. The Cisco certified technician must be able to perform repair (hardware failure) services on Cisco data center products, including backup and recovery of software and configuration, verify safety and environment requirements, recognize the type of connection and cable required and perform basic physical layer troubleshooting.
NEW QUESTION 51
Which three troubleshooting procedures do you perform when there is no power to a Cisco UCS B250 M2 Blade Server? (Choose three.)
- A. Reseat the memory DIMMs.
- B. Check the back of the blade to ensure that there is no damage to the connection that goes into chassis.
- C. Check the CPU sockets for bent pins.
- D. Reseat the blade in the same slot in the chassis.
- E. Decommission and acknowledge the blade.
- F. Move the blade to another slot in the chassis.
Answer: B,D,F
NEW QUESTION 52
With which data center type can a company lease the equipment and infrastructure?
- A. Green technology data center
- B. Managed services data center
- C. Enterprise data center
- D. Colocation data center
Answer: B
NEW QUESTION 53
If the Overall Status for a Cisco UCS B-Series Blade Server indicates a failure in the Cisco UCS Manager, such as discovery-failed, which statement is true?
- A. The server shuts down.
- B. The endpoints on that server cannot be upgraded.
- C. The server automatically reboots reboot in 3 minutes.
- D. The server is online, but the administrator cannot assign a service profile to that blade.
Answer: B
NEW QUESTION 54
Refer to the exhibit.
What is the name of this rack-mount server?
- A. Cisco UCS C460 Rack-Mount Server
- B. Cisco UCS C420 Rack-Mount Server
- C. Cisco UCS C220 Rack-Mount Server
- D. Cisco UCS C240 Rack-Mount Server
Answer: B
NEW QUESTION 55
Which Cisco Nexus 5000 Series model supports 1/10G BASE-T ports?
- A. Cisco Nexus 5596T
- B. Cisco Nexus 5548UP
- C. Cisco Nexus 5548P
- D. Cisco Nexus 5596UP
Answer: A
NEW QUESTION 56
When a host firmware package policy is created, what must it be associated with to upgrade the BIOS?
- A. blade or blade pool
- B. service template
- C. boot policy
- D. service profile
Answer: D
NEW QUESTION 57
Refer to the exhibit.
Which item does A represent?
- A. Virtual Interface Card for Cisco UCS B420 M3 Blade Servers
- B. Emulex Adapter Card for Cisco UCS B420 M3 Blade Servers
- C. mLOM for Cisco UCS B420 M3 Blade Servers
- D. Virtual Emulex Adapter Card for Cisco UCS B420 M3 Blade Servers
- E. SuperCap module for Cisco UCS B420 M3 Blade Servers
Answer: C
NEW QUESTION 58
What is the command to provide details pertaining to the state of the cluster?
- A. Show cluster extended-state
- B. Show cluster state
- C. Show cluster
- D. Show extended cluster state
Answer: A
NEW QUESTION 59
Which supervisor module is supported by a Cisco Nexus 7700 Series Switch?
- A. first-generation supervisor module
- B. third-generation supervisor enhanced module (Sup3E)
- C. second-generation supervisor enhanced module (Sup2E)
- D. second-generation supervisor module (Sup2)
Answer: C
Explanation:
Explanation/Reference:
NEW QUESTION 60
What is the wire transmission speed for 100GBASE-ER4 Ethernet?
- A. 1 Gb/s
- B. 100 Gb/s
- C. 10 Gb/s
- D. 100 Mb/s
Answer: B
Explanation:
Explanation/Reference:
updated.
NEW QUESTION 61
To confirm the installation of a B-Series Server, which GUI based management tool will be used?
- A. Console Access
- B. UCSM (UCS Manager)
- C. Windows 10
- D. CIMC (Cisco Integrated Management Controller)
Answer: B
NEW QUESTION 62
Which two provide connectivity to Fabric Extenders? (Choose two.)
- A. UCS S-Series Storage Servers
- B. UCS 6300 series
- C. UCS E-Series Servers
- D. UCS B-Series Servers
- E. UCS 6400 series
Answer: B,E
NEW QUESTION 63
In Cisco UCS C480 M5 server, which PCle slot is the default slot for the rear RAID controller when the rear drive module is used with SAS/SATA drives?
- A. PCle slot 09
- B. PCle slot 11
- C. PCle slot 12
- D. PCle slot 10
Answer: B
NEW QUESTION 64
Refer to the exhibit.
Which item does B represent?
- A. PCle Riser 1
- B. PCle Riser 2
- C. mLOM
- D. Power Supply
- E. Rear 2.5-inch drive bays
Answer: B
NEW QUESTION 65
Which command can be used to exit to EXEC mode from this current mode? switch(config-if) #
- A. quit
- B. Ctrl-C
- C. exit
- D. end
- E. Ctrl-L
Answer: D
NEW QUESTION 66
Which command saves the active configuration to NVRAM?
- A. copy backup-config active-config
- B. copy active-config backup-config
- C. copy startup-config running-config
- D. copy running-config startup-config
Answer: D
NEW QUESTION 67
Refer to the exhibit.
This image shows a CPU Pick-and-Place tool and a CPU Socket Protective Cap Removal tool. Which types of Cisco UCS servers and Intel Xeon processors do these tools support?
- A. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5-2400 Series processors
- B. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2600 Series processors
- C. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5-2600 Series processors
- D. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2400 Series processors
Answer: B
NEW QUESTION 68
Which two commands allow you to view the state of high availability between the two clustered Fabric Interconnects? (Choose two.)
- A. show cluster HA status
- B. show cluster state extended
- C. show cluster state
- D. show cluster extended-state
Answer: C,D
NEW QUESTION 69
What enables NVM Express host software to communicate with nonvolatile memory?
- A. PCIe
- B. SCSI
- C. SAS
- D. SATA
Answer: A
Explanation:
Explanation/Reference: https://nvmexpress.org/wp-content/uploads/NVM-Express-1_4-2019.06.10-Ratified.pdf page 6
NEW QUESTION 70
Which tool does a network administrator not need when installing hardware?
- A. cable tester
- B. needle-nose pliers
- C. PCMCIA memory
- D. wrench set
- E. soldering iron with grounded tip
- F. cable wraps
Answer: E
NEW QUESTION 71
Refer to the exhibit.
Which call-out accurately shows the current running version of the Cisco UCS Manager management software?
- A. C - Interface Card 1 running version 1.4(1m)
- B. A - UCS Manager running version 1.4(1m)
- C. D - Kernel running version 4.2(1)N(1.4m)
- D. B - IO Module 1 running version 1.4(1m)
Answer: B
NEW QUESTION 72
Refer to the exhibit.
This image shows a CPU Pick-and-Place tool and a CPU Socket Protective Cap Removal tool.
Which types of Cisco UCS servers and Intel Xeon processors do these tools support?
- A. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5- 2600 Series processors
- B. Cisco UCS B22 Blade Server, C22 Rack Server, and C24 Rack Sever with Intel Xeon E5- 2400 Series processors
- C. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2600 Series processors
- D. Cisco UCS B200 M3 Blade Server, B420 M3 Blade Server, C220 Rack Server, C240 Rack Sever, and C420 Rack Sever with Intel Xeon E5-2400 Series processors
Answer: C
NEW QUESTION 73
Which Cisco NX-OS command displays kernel uptime?
- A. show license
- B. show boot
- C. show interface
- D. show version
- E. show module
Answer: D
NEW QUESTION 74
During the auto-sync firmware upgrade process, what should be your initial input entered once the Fabric Interconnect boots up?
- A. auto-sync
- B. console
- C. upgrade firmware
- D. gui
Answer: B
NEW QUESTION 75
Which action should the administrator take before physically removing a blade server for maintenance or replacement?
- A. Decommission the server.
- B. Force the server to shut down.
- C. Disassociate the service profile.
- D. Perform a graceful shutdown of the server.
Answer: A